GBC SCIENTIFIC LLC AMERICAS
  • Home
  • ICPMS-TOF
    • ICP-TOFMS OptiMass 9500
    • OptiMass 9600 ICP-TOFMS
    • ICPMSTOF-ETV
  • ICP-OES
    • Integra 6000
    • Quantima
    • ICP-OES-ETV
  • XRD
    • XRD
  • AAS
    • SavantAA Zeeman enduro
    • SavantAA AAS
    • SavantAA Σ AAS
    • XplorAA AAS
    • GeminAA Plus
    • enduro T2100
  • UV-VIS
    • Cintra 4040
    • Cintra 3030
    • Cintra 2020
    • Cintra 1010
  • ABOUT US
  • Contact Us
  • XRD Software
  • More
    • Home
    • ICPMS-TOF
      • ICP-TOFMS OptiMass 9500
      • OptiMass 9600 ICP-TOFMS
      • ICPMSTOF-ETV
    • ICP-OES
      • Integra 6000
      • Quantima
      • ICP-OES-ETV
    • XRD
      • XRD
    • AAS
      • SavantAA Zeeman enduro
      • SavantAA AAS
      • SavantAA Σ AAS
      • XplorAA AAS
      • GeminAA Plus
      • enduro T2100
    • UV-VIS
      • Cintra 4040
      • Cintra 3030
      • Cintra 2020
      • Cintra 1010
    • ABOUT US
    • Contact Us
    • XRD Software
GBC SCIENTIFIC LLC AMERICAS
  • Home
  • ICPMS-TOF
    • ICP-TOFMS OptiMass 9500
    • OptiMass 9600 ICP-TOFMS
    • ICPMSTOF-ETV
  • ICP-OES
    • Integra 6000
    • Quantima
    • ICP-OES-ETV
  • XRD
    • XRD
  • AAS
    • SavantAA Zeeman enduro
    • SavantAA AAS
    • SavantAA Σ AAS
    • XplorAA AAS
    • GeminAA Plus
    • enduro T2100
  • UV-VIS
    • Cintra 4040
    • Cintra 3030
    • Cintra 2020
    • Cintra 1010
  • ABOUT US
  • Contact Us
  • XRD Software

ICPMS-TOF OptiMass 9600

  

ICP-oTOFMS -  

The OptiMass 9600 ICP Time-of-Flight Mass Spectrometer (ICP-TOFMS) builds on the success of the OptiMass 9500 and provides advanced Octopole Collision Cell (OCC) technology for superior interference management.

This third generation bench top ICP-TOFMS overcomes the major limitations associated with quadrupole ICP-MS instrumentation. Detection limits equivalent to those achievable with a quadrupole instrument can be achieved for amu 1 to 260 within seconds. This inherent speed allows higher sample throughput with the use of conventional sample introduction systems.

In hardware terms these improvements have lead to reduced maintenance, more robust plasma performance, enhanced sample introduction capability and improved system sequencing.

In software terms many new features have been added.
The new auto optimization software function allows the software to optimize the instrument parameters automatically to give the best sensitivity. The OptiMass 9600 software contains a powerful semi-quantitative analysis mode. This mode uses factory defined relative sensitivity factors (RSF) to define the detector response to an unknown concentration of analyte. The simultaneous nature of the OptiMass 9600 allows not only semi-quantitative, but also retrospective semi-quantitative analysis.

When comparative studies are required, such as in Forensic Science, it can be very useful to use the new Fingerprinting software. This type of analysis makes the best use of the scans to be compared to determine how closely they match. This type of analysis entails a statistical comparison of a test spectrum to a spectrum of a known material. This can be a comparison of an SRM to sample material or the comparison of scene-of-crime evidence to samples recovered from suspect’s residence, vehicle or personal belongings. Before implementation of this type of analysis the correct sampling protocols need to be established. The OptiMass 9600 then provides a rapid multi-element analysis providing complete spectral data collection. This coupled with the powerful statistical fingerprinting software of the 9600 provides the complete package for comparative analysis. The true simultaneous multi-element capability of the time-of-flight technology used in the OptiMass 9600 ensures that no information is lost from analysis of small volume samples often found in scene-of-crime scenarios.

The high speed data collection rate enables transient signals generated from, e.g., single shot laser ablation, electro-thermal vaporization or flow injection, to be sampled 30,000 times per second and 50 integrated full mass spectra to be displayed every second. This opens up a range of applications that previously have been hindered by the slow sequential nature of quadrupole or magnetic sector field mass spectrometers.

For further information, please contact us.